RoboteQ AX1500 Control Settings, Loading, Changing Controller Parameters, Controller Input

Models: AX2550 AX1500

1 186
Download 186 pages 53.05 Kb
Page 165
Image 165
Loading, Changing Controller Parameters

Loading, Changing Controller Parameters

When starting Roborun, this screen is filled with the default values. If the controller is con- nected to your PC, Roborun will automatically detect it and ask you if you wish to read its settings.

The controller’s setting in the PC at can be read any other time by pressing the “Load from Controller” button. After changing a parameter, you must save it to the controller manually by pressing the “Save to Controller” button.

Control Settings

1

2

3

4

5

6

FIGURE 90. Control modes setting screen

The screen shown in Figure 90 is used to view and change the controller’s main control modes. Below is the list of the parameters accessible from this screen:

1- Controller Input:

This pull down menu allows the user to select the RS232, R/C or Analog mode of opera- tion. If the RS232 mode is selected, a check box will appear, allowing you to enable or dis- able the RS232 Watchdog. For more information on these modes, see

R/C Operation” on page 101

Serial (RS-232) Controls and Operation” on page 121

RS-232 Watchdog” on page 128

Analog Control and Operation” on page 113

2- Motor Control Mode

This pull down menu is used to choose whether the controller will operate in Separate or Mixed mode. For more information on these modes, see “Selecting the Motor Control Modes” on page 40.

3- Input Command Adjustment

These pull down menus will let you select one of five conversion curves on each of the input command values. See “Command Control Curves” on page 46.