Controller Commands and Queries

values represent the actual speed measured by the tachometer. When used in position mode, the values represent the actual motor position measured by a potentiometer. In all other modes, the values represent the measured voltage (0 to 5V) applied to the analog inputs. The values are signed Hexadecimal numbers ranging from -127 to +127. The -127 value represents 0V at the input, the 0 value represents 2.5V, and the +127 value repre- sents +5V.

Analog 1 and 2

 

Syntax:

?p or ?P

Analog 3 and 4

 

Syntax:

?r or ?R

Reply:

nn

 

mm

Where:nn = analog input 1 (or 3) value, speed or position

mm= analog input 2 (or 4) value, speed or position

Notes:

The command returns a signed hexadecimal number where 0 to +127 is represented by 00 to 7F, and -1 to -127 is represented by FF to 80 respectively.

On controllers prior to RevB, querying Analog inputs 3 and 4 will return a meaningless number.

Query Heatsink Temperatures

Description:

This query will cause the controller to return values based on the temperature measured by internal thermistors located at each heatsink side of the controller. Because NTC ther- mistors are non-linear devices, the conversion or the read value into a temperature value requires interpolation and a look up table. Figure 39 on page 69 shows this correlation.

Sample conversion software code is available from Roboteq upon request. The values are unsigned Hexadecimal numbers ranging from 0 to 255. The lowest read value represents the highest temperature.

Syntax:

?m or ?M

Reply:nn mm

Where:nn = thermistor 1 read value

mm= thermistor 2 read value

Notes:

The hexadecimal format is intended to be deciphered by a microcontroller. When exercis- ing the controller manually, you may use the Decimal to Hexadecimal conversion table on page 166.

Query Battery Voltages

Description:

This query will cause the controller to return values based on two internally measured volt- ages: the first is the Main Battery voltage present at the thick red and black wires. The sec- ond is the internal 12V supply needed for the controller’s microcomputer and MOSFET

AX2550 Motor Controller User’s Manual

141