RoboteQ AX2850 user manual Amps Limit, Bit Definition See pages

Models: AX2850

1 200
Download 200 pages 6.02 Kb
Page 146
Image 146

Serial (RS-232) Controls and Operation

This parameters selects the various open loop and closed loop operating modes as well as the feedback method.

Bit

Definition

 

 

See pages

2:0

Motor Control Mode

0 = A & B separate speed open loop

page 42

 

 

(default)

page 97

 

 

 

 

 

 

1

= A & B mixed speed open loop

page 85

 

 

 

 

 

 

2

= A speed open loop, B position

 

 

 

3

= A & B position

 

 

 

4

= A & B separate speed closed loop

 

 

 

5

= A & B mixed speed closed loop

 

 

 

6

= A speed close loop, B position

 

 

 

 

 

 

6:3

Reserved

 

 

 

 

 

 

 

6

Ch1 Feedback type

0 = Analog

page 97

 

 

1

= Encoder

page 85

 

 

 

 

7

Ch2 Feedback type

0 = Analog

 

 

 

1

= Encoder

 

 

 

 

 

 

Amps Limit

Address:

^02

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the controller’s Amps limit. Note that this limits the amps flow- ing out of the power supply. Current flowing through the motors may be higher.

Bit

Definition

 

 

See pages

 

 

 

 

3:0

Coarse Amps

0 = 30A

page 44

 

 

1

= 45A

 

 

 

2

= 60A

 

 

 

3

= 75A

 

 

 

4

= 90A

 

 

 

5

= 105A (default)

 

 

 

6

= 120A

 

 

 

 

 

7:4

Fine Amps

Substract this number from the Coarse

 

 

 

Amps value

 

 

 

 

 

 

146

AX2550 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 146
Image 146
RoboteQ AX2850 user manual Amps Limit, Bit Definition See pages