Serial (RS-232) Controls and Operation

TABLE 28. Controller Status Register Definition

Bit

Fault Condition

Effect

 

 

 

5

Confirmed Short Circuit

Permanent

 

 

 

6

Confirmed Encoder Error

Permanent

 

 

 

7

Emergency Stop Pressed

Permanent

 

 

 

Controller Identification Register

Address:

^8A

Access:

Read Only

Effective:

Instantly

This register may be used to query the Controller’s model and some of its optional hard- ware configurations.

TABLE 29. Controller Identification Register Definition

Bit

Model or Function

0AX500

1AX1500

2AX2500

3AX3500

4Unused

5Encoder Present

6Short Circuit Detection Present

7Unused

Current Amps Limit Registers

Address:

^8B - Channel 1

 

^8C - Channel 2

Access:

Read Only

Effective:

Instantly

These registers can be polled to view what the Amps limit is at the current time. This limit normally is the one that is preset by the user except when the controller is operating at high temperature, in which case the allowable current drops as temperature rises. See “Temperature-Based Current Limitation” on page 44.