RoboteQ AX2850 user manual Connecting Switches or Devices to Input F

Models: AX2850

1 200
Download 200 pages 6.02 Kb
Page 61
Image 61

Connecting Switches or Devices to Input F

Input E is a high impedance input with a pull-up resistor built into the controller. Therefore it will report an On state if unconnected, and a simple switch as shown on Figure 29 is nec- essary to activate it.

+5V Out 14

Input E 8

Ground 5

50kOhm

10kOhm

50kOhm Internal Buffer

FIGURE 29. Switch wirings to Input E

The status of Input E can be read in the RS232 mode with the ?i command string. The con- troller will respond with three sets of 2 digit numbers. The status of Input E is contained in the first set of numbers and may be 00 to indicate an Off state, or 01 to indicate an On state.

This input is not available on the AX2850 or on the AX2550 with the Encoder Module installed.

Remember that, in RevB hardware, InputE is shared with the Analog Input 4. If an analog sensor is connected, the controller will return a Digital value of 0 if the voltage is lower than 0.5V and a value of 1 if higher

Connecting Switches or Devices to Input F

Input F is a general purpose digital input. This input is only active when in the RS232 or Analog modes. In R/C mode, this line is used as the radio channel 2 input.

When left open, Input F is in an undefined stage. As shown in the figure below, a pull down or pull up resistor must be inserted when used with a single pole switch. The resistor may be omitted when used with a dual pole switch.

AX2550 Motor Controller User’s Manual