Activating Brake Release or Separate Motor Excitation

TABLE 8. Left/Right Adjustment Parameter selection

Parameter Value

Speed Adjustment

 

Parameter Value

Speed Adjustment

 

 

 

 

 

5

-1.5%

 

12

4.5%

 

 

 

 

 

6

-0.75%

 

14

5.25%

 

 

 

 

 

Activating Brake Release or Separate Motor Excitation

The controller may be configured so that the Output C will turn On whenever one of the two motors is running. This feature is typically used to activate the mechanical brake release sometimes found on motors for personal mobility systems. Likewise, this output can be used to turn on or off the winding that creates the armature’s magnetic field in a separate excitation motor. This function is disabled by default and may be configured using the Roborun PC utility. See “Loading, Changing Controller Parameters” on page 181. See “Connecting devices to Output C” on page 59 for details on how to connect to the output.

Emergency Shut Down Using Controller Switches

In case of emergency, it is possibly to cause the controller to cut off the power to the motors by depressing the Program and Set buttons simultaneously as shown in the figure below. The controller will stop immediately without delay.

Program

Set

 

Reset

Press the two buttons simultaneously to cause an emergency stop

FIGURE 23. Activating an Emergency Stop

After and Emergency Stop condition, the controller must be reset or powered Off and On to resume normal operation.

Emergency Stop using External Switch

An external switch can be added to the AX2550 to allow the operator to stop the control- ler’s output in case of emergency. This controller input can be configured as the “Inverted” detection instead of Emergency Stop. The factory default for this input is “No Action”.

AX2550 Motor Controller User’s Manual

51

Page 51
Image 51
RoboteQ AX2850 Activating Brake Release or Separate Motor Excitation, Emergency Shut Down Using Controller Switches