RoboteQ AX2850 user manual Programmable Parameters List, See

Models: AX2850

1 200
Download 200 pages 6.02 Kb
Page 175
Image 175

Programmable Parameters List

This table shows only the parameters that can be programmed using the switches and display. Other less commonly used parameters exist and are only accessible and pro- grammable using the Configuration Utility (page 177) or the RS232 commands (page 143).

TABLE 35. Parameters accessible using the controller’s switches and display

 

 

 

 

 

See

Order

Letter

Description

Possible Values (default)

pages

1

I

Input Command

(0) = R/C Radio mode (default)

page 109

 

 

mode:

1

= RS232 full duplex, no watchdog

page 131

 

 

 

 

 

 

2

= RS232 half duplex, with watchdog

 

 

 

 

3

= Analog mode

page 123

 

 

 

 

 

2

C

Motor Control mode

(0) = Separate A, B, speed control, open

page 42

 

 

 

loop (default)

 

 

 

 

1

= Mixed A & B, speed control, open loop

 

 

 

 

For safety reasons, the modes below

 

 

 

 

cannot be selected using the switches.

 

 

 

 

2

= Speed control on A, open loop. Posi-

 

 

 

 

tion control on B

 

 

 

 

3

= A & B Position control

 

 

 

 

4

= Separate A, B, speed control, closed

 

 

 

 

loop

 

 

 

 

5

= Mixed A & B, speed control, closed

 

 

 

 

loop

 

 

 

 

6

= Speed control on A, closed loop. Posi-

 

 

 

 

tion control on B

 

 

 

 

 

 

3

A

Amp limit

0 = 30A

page 44

 

 

 

1

= 45A

 

 

 

 

2

= 60A

 

 

 

 

3

= 75A

 

 

 

 

4

= 90A

 

 

 

 

(5) = 105A default

 

 

 

 

6

= 120A

 

 

 

 

Amps may be set with a finer resolution

 

 

 

 

using the PC utility

 

 

 

 

 

 

4

S

Acceleration

0 = very slow

page 47

 

 

 

1

= slow

 

 

 

 

(2) = medium (default)

 

 

 

 

3

= medium

 

 

 

 

4

= fast

 

 

 

 

5

= fastest

 

 

 

 

Acceleration may be set with a finer resolu-

 

 

 

 

tion using the PC utility

 

 

 

 

 

 

 

AX2550 Motor Controller User’s Manual