TABLE 31. Encoder Registers

Address

Parameter Description

Size

Access

 

 

 

 

*98

Destination Register 1 MSB (bits 31 to 24)

 

 

 

 

 

 

*99

Destination Register 1 (bits 23 to 16)

4 bytes

Full

 

 

 

 

*9A

Destination Register 1 (bits 15 to 8)

 

 

 

 

 

 

*9B

Destination Register 1 LSB (bits 7 to 0)

 

 

 

 

 

 

*9C

Distance 1 (when Position Mode enabled)

1 byte

Full

 

 

 

 

*8D

Distance 2 (when Position Mode enabled)

1 byte

Full

 

 

 

 

*86

Speed 1

1 byte

Full

 

 

 

 

*87

Speed 2

1 byte

Full

 

 

 

 

*A2

Time Base for speed computation of Encoder 1. Multiply

1 byte

Full

 

this number by 256us to obtain the actual Time Base period.

 

 

 

 

 

 

*A3

Time Base for speed computation of Encoder 2. Multiply

1 byte

Full

 

this number by 256us to obtain the actual Time Base period.

 

 

 

 

 

 

*A4

Encoder threshold level (see “Voltage Levels, Thresholds

1 byte

Full

 

and Limit Switches” on page 76

 

 

 

 

 

 

*A5

Distance divider

1 byte

Full

 

 

 

 

*A6

Mode Selection

1 byte

Limited

 

 

 

 

Important Warning

Do not alter any other area locations, as this may cause program execution failure inside the encoder module.

Register Description

Encoder Hardware ID code

Address: *84

Returns a 4-bit number identifying the encoder module hardware version and the status of two on-board jumpers. For Roboteq use only.

Switch Status

Address: *85

Returns a 4 bit number (4 least significant bits of the byte), each representing the state of one of the limit switches when installed. The ?W command described at “Read Encoder Limit Switch Status” on page 157 is a preferred method for reading this information.

Speed or Distance 1 or 2

Address:

*86 - Channel 1

 

*87 - Channel 2

160

AX2550 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 160
Image 160
RoboteQ AX2850 user manual Register Description, Encoder Hardware ID code, Switch Status, Speed or Distance 1 or