Serial (RS-232) Controls and Operation

Bit

Definition

 

 

See pages

 

 

 

 

5:4

Input E

Unavailable when Encoder Module is

page 52

 

 

present

page 52

 

 

 

 

 

 

(00) = No action (default)

 

 

 

01

= Cut FET power when Input E is Low

 

 

 

10

= Activate output C

 

 

 

11 = Cut FET when Input E is High

 

 

 

 

 

7:6

Input F

(00) = No action (default)

page 52

 

 

01

= Cut FET power when Input E is Low

page 52

 

 

10

= Activate output C

 

 

 

11 = Cut FET when Input E is High

 

 

 

 

 

 

RC Joystick or Analog Deadband

Address:

^06

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the amount of joystick or potentiometer motion can take place around the center position without power being applied to the motors.

Bit

Definition

See pages

 

 

 

7:0

Values are for Joystick deadband

page 117

 

0

= no deadband

or

 

1

= 8%

page 127

 

(2) = 16% (default)

 

 

3

= 24%

 

 

4

= 32%

 

 

5

= 40%

 

 

6

= 46%

 

 

7

= 54%

 

 

 

 

 

Exponentiation on Channel 1 and Channel 2

Address:

^08 - Channel 1

 

^09 - Channel 2

Access:

Read/Write

Effective:

Instantly