Table 4-1. Aspect Ratio Settings (continued)

 

Remote

 

 

 

 

 

Aspect Ratio

Control

 

 

Description

 

Key

 

 

 

 

 

 

 

 

 

 

 

 

VirtualWide

V WIDE

 

 

 

 

VirtualWide scales a 4:3

 

 

 

 

 

 

 

 

 

 

image NON-linearly (more

 

 

 

4:3 Image on

 

 

on the sides than in the

 

 

 

 

 

center) to fit a 16:9 screen.

 

 

 

16:9 Screen (Display)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4:3 Image on 16:9 Display with VirtualWide

Use the controls in the Picture Adjust menu to calibrate your Crystal Series LCD for optimum picture quality.

The Crystal Series LCD has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these standards to obtain optimal picture quality from Runco video display devices. Accordingly, Runco recommends that setup and calibration be performed by an ISF-certified installation technician.

All signal types require separate processing. Therefore, you need to calibrate each input separately.

When you change a picture quality setting, save the change to a

Note preset afterwards. Otherwise, the change will be lost when a different input is selected. (Picture quality settings are saved for each input and resolution separately.) For information about saving settings, refer to Save Settings on page 33.

Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Runco recommends using the following calibration tools for best results:

External test pattern source – Ovation Multimedia, Digital Video Essentials or AVIA test DVD or equivalent.

A blue filter (provided with many test DVDs), for color level and tint adjustments.

Connect your test pattern source to the input that you are calibrating and proceed as follows. Perform the adjustments in the order listed here.

Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) Figure 4-2shows a typical PLUGE pattern.

Picture Adjust

Picture Adjust Brightness

Contrast

Color

Tint

Sharpness

DNR

MPEG NR

Backlight

Color Temp.

Gamma

Save Settings

Restore Settings

CX-47HD/CX-OPAL47/CX-65HD Installation/Operation Manual

29

Page 43
Image 43
Runco CX-65HD, CX-OPAL47, CX-47HD operation manual Picture Adjust