Information ➤

Operation

Information

Information

Signal

System

Field Service

Manufacturing

Signal / System: Select Information from the Main Menu, then choose either Signal or System to display information about the current input signal (resolution, frequency, type et cetera) and installed firmware versions, as well as other information that uniquely identifies your DHD Controller and display device.

Should you ever need to contact Runco Technical Support, this information will help them answer your questions or resolve product performance issues.

Signal

 

Input Source

HDMI 1

Signal Format

1080p/60

Input Resolution

1920x1080

Vertical Freq

59.94 Hz

Horizontal Freq

67.500 kHz

Pixel Clock

148.500 MHz

Color Space

REC709

Sync Type

Separate

Memory Preset

ISF Night

 

 

System

Model

DHD3

Display Name

Q-750d

Output Resolution

1920x1080

Serial Number

00000000

Boot Version

3.0

Firmware Version

3.4

Micro Version

3.3

 

 

Calibration

Calibration

ISF Settings

Display Color

Input Image

Input Color

Save ISF Night

Save ISF Day

Copy/Paste

Output Shift

Splash Configure

OSD Position

Field Service / Manufacturing: The Field Service and Manufacturing menus are password-protected and intended for use only by Runco service personnel and factory technicians.

Use the Calibration menu to perform advanced picture quality adjustments. This menu

should be used by ISF-certified technicians only.

You must enter a passcode to access the Calibration menu.

Note

To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the Memory Presets menu (see page 58) or use the corresponding remote control buttons.

Display Color: Use the Display Color settings to adjust the color balance at the DHD Controller output. These settings are saved independently for each input and display mode.

Gain: Use the Gain controls to correct color imbalances in the bright areas of the image. A good way to do this is to use a test pattern consisting mostly of solid white areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red (Pr), green (Y) or blue (Pr), decrease the Gain for that color.

Offset: Use the Offset controls to correct color imbalances in the dark areas of the image. A good way to do this is to use a test pattern consisting mostly of dark gray areas, such as a 30 IRE “window” pattern. If the gray areas contain traces of red (Pr), green (Y) or blue (Pr), decrease the Offset for that color.

Gamma: Select Gamma from the Display Color menu to choose a DLP de-gamma curve. The available settings are 1.8, 2.0, 2.2, 2.35 and 2.5.

Used correctly, the Gamma control can improve contrast while maintaining good details for blacks and whites.

60