Operation

Table 4-3lists the x- and y-coordinates for each primary and secondary color component.

Table 4-3. x/y Color Gamut Values

 

 

Color Gamut Settings and Associated x/y Values

 

 

Primary

 

 

 

 

 

 

 

 

 

 

REC709

SMPTE “C”

 

EBU

 

DCI

Color

 

 

 

 

 

 

 

 

 

 

 

 

 

x

y

x

y

x

 

y

x

 

y

 

 

 

 

 

 

 

 

 

 

 

Red

0.640

0.330

0.635

0.340

0.640

 

0.330

0.680

 

0.320

 

 

 

 

 

 

 

 

 

 

 

Yellow

0.419

0.505

0.421

0.506

0.418

 

0.502

0.425

 

0.548

 

 

 

 

 

 

 

 

 

 

 

Green

0.300

0.600

0.305

0.595

0.290

 

0.600

0.265

 

0.690

 

 

 

 

 

 

 

 

 

 

 

Cyan

0.225

0.329

0.228

0.326

0.220

 

0.329

0.205

 

0.360

 

 

 

 

 

 

 

 

 

 

 

Blue

0.150

0.060

0.155

0.070

0.150

 

0.060

0.150

 

0.060

 

 

 

 

 

 

 

 

 

 

 

Magenta

0.321

0.154

0.318

0.162

0.328

 

0.158

0.342

 

0.154

 

 

 

 

 

 

 

 

 

 

 

PCE: To use the Personal Color Equalizer to define a custom color gamut, choose the “PCE” Color Gamut setting (refer to Color Gamut on page 62). Then, choose PCE from the Display Color menu and press ENTER.

Note

The DHD Controller uses the PCE settings for all display modes on

a given input.