Alignment and Adjustmens

-Paper Jam at the paper exit area

There is a paper at exit area

After cover Open , Paper must be removed, and then close the cover

-Motor Lock Error

Motor does not run or runs abnormal speed

Motor or Main board must be checked

-LSU Motor Lock Error

LSU motor does not run or runs abnormal speed

Hsync is not detected

LSU or Main board must be checked

-Transfer Belt Error

ITB home sensor is not checked for a normal time

ITB must be checked

-Fuser Over Heat error

Temperature of fuser is high

Fuser or Main board must be checked

-Fuser Low Heat error

Temperature of fuser is low

Fuser or Main board must be checked

-Dev. Home error

Home of Development is not checked or checked at the abnormal time

Clutch of Development or Main board must be checked

-ADC not Confirm Error

Signal of confirmation for ADC is not detected

Main board must be checked

6-18

Service Manual

Samsung Electronics

 

Page 78
Image 78
Samsung CLP-300 XSG manual Alignment and Adjustmens