<Hint>

Scene memories stored in the scene numbers (00 to 99) are preserved even if the power is turned off. However, a temporary memory stored in the Temporary numbers disappear and all the parameters return to the default "Un-defined" settings when the power is turned off, though they do not disappear when changing the pro- gram. If you want to store the temporary memory to a scene number (00 to 99), recall the temporary number before turning off the power and store the memory to the desired Scene number (00 to 99).

Recalling a scene memory

You can recall the settings stored in scene memories.

1.Press the [SCENE-RECALL] key.

The display shows the screen for selecting the scene number.

2.Use the [JOG] dial to select the desired scene number to be recalled, and press the [ENTER/YES] key.

After "Scene Recalled" appears on the display, the selected scene is recalled and the display changes to the Normal display.

<Hints>

The contents recalled differ depending on the settings in the "Fader recall" menu in the SETUP mode.

See "Settings for fader recall" menu in the SETUP mode for the detailed information.

Regardless of the current physical positions of channel and master faders, audio is output at the fader position location when they were stored. We suggest you turn the audio volume down when recalling a scene memory to prevent accidentally accessing high-volume sound.

When switching the display to the fader adjust, level adjust or fader view screen, the [FADER ADJUST] key may flashes (when the fader recall setting is not set to "Off").

This indicates that the fader position in the current scene does not match the physical fader position. In such a case, you can turn off the key by adjusting the fader to the position in the current scene or by adjusting the level to the current physical position. See the following description for details about the fader adjustment and level adjustment.

Level adjust

When recalling a scene memory, if the recalled fader level does not match the current physical fader posi- tion (the red indicator of the [FADER ADJUST] key flashes), you can adjust the level to match the current fader position.

1.Press the [FADER ADJUST] key while holding down the [SHIFT] key.

The unit enters the Level adjust mode.

The fader icons appear on the display, as well as flashing "Sure?". The recalled fader positions are shown as fader knob positions while the current fader positions are indicated by “>” and “<”. In the following example, all recalled fader positions are at the lowest positions.

Flashing

2.Press the [ENTER/YES] key.

The display shows "Completed!", immediately followed by the Normal display after each actual (internal) fader position is set to match the corresponding physical fader position. The flashing indicators of the FADER ADJUST turn off. With the example above, all actual faders are set to minimum.

Fader adjust

When recalling a scene memory, if the recalled fader level does not match the current physical fader posi- tion (the red indicator of the [FADER ADJUST] key flashes), you can move the physical faders to match the current fader positions of the scene.

The following description is assumed that "Fader recall setting" of the SETUP mode is set to "CH&MST".

1.Press the [FADER ADJUST] key alone.

The unit enters the Fader adjust mode.

The fader icons appear on the display, as well as flashing "Select CH!".

The recalled fader positions are shown as fader knob positions while the current fader positions are indicated by “>” and “<”.

Flashing

If you press the [FADER ADJUST] key when the fader recall setting is set to "Off", the display shows "Fader Recall Off" and then returns to the Normal display.

2.Select the channel to be adjusted by pressing the corresponding [CH STATUS/CH SEL] key, and move the corresponding physical fader.

In the screen example below, the physical fader position of channel 1 matches the recalled fader position.

62

Page 62
Image 62
Fostex VF160EX operation manual Recalling a scene memory, Level adjust, Fader adjust