110
Flashing

You can load data using the S/PDIF or adat digital signal via the [DIGITAL/DATA IN] jack.

*Use an external device that supports 44.1 kHz sampling frequency (the same as the VF160EX).

Connecting to an external device

Connect the [DIGITAL/DATA IN] jack to the digital

output jack of the external digital device.

<Notes>
The DIGITAL/DATA OUT jack accommodates either
the S/PDIF (optical) or adat digital signal selected.
Though the S/PDIF (optical) and adat digital signal
use the same connector shape, the signal formats are
different.
Do not do anything, such as unplug the optical cable,
that interrupts the digital signal until the loading
operation is completed. Otherwise, the unit may
generates a noise which damages an external device.
When using the S/PDIF signal, if your DAT only
provide the coaxial (RCA) digital input jack and does
not provide the optical jack, use the optional COP-1/
96kHz (optical/coaxial converter).
Do not connect digital signals for both directions
between the VF160EX and the external device (i.e.
the digital output of the VF160EX to the digital input
of the external device and the digital output of the
external device to the digital input of the VF160EX),
which may form a digital loop and cause feedback.

Setting the external device

1. Make preparations of the external device for outputting

the digital signal.

2. Locate the beginning of the pilot signal for the song data.

*See the operation manual of the external device for
the detailed information.

Loading data

You can load data via the "Load PGM" menu in the

SETUP mode.

<Details about "Load PGM" menu>

•Input signal options: OPT (adat or S/PDIF)
IDE (CD-1A/EX)
•Program options: P01 to P99 (an individual Program)
•Track options:
* When using S/PDIF or adat:
Tracks 1-8, Tracks 1-16, Tracks 1-24, Tracks 9-16,
Tracks 9-24 or Tracks17-24.
* When using a CD-RW/CD-R disk:
All tracks (1-24) is selected automatically. (You can
select tracks individually when loading a WAV file).
1. Press the [SETUP] key to enter the Setup mode.
The display shows the screen for selecting the Setup menu.

2. Use the [JOG] dial to select "Load PGM" and press the

[ENTER/YES] key.
The display shows the screen for selecting the device
from which the data is loaded. "IDE" flashes.
2
1RL
IN OUT
IN OUT
AVIS:
OPTICAL
AC-IN
POWER
FOOT SW
DIGITAL/DATA
MIDI
ST OUT
AUX SEND
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.

3. Use the [REWIND] key to select "OPT" and press the

[ENTER/YES] key.
The display shows the screen for selecting "SPDIF" or
"adat", in which "SPDIF" flashes.
Flashing
If you load data using the adat digital signal, select
"adat". If you load data using the S/PDIF digital signal,
select "SPDIF".
Loading data using the S/P DIF or adat digital signal
adat or DAT