On/Off of phantom power setting [“Phantom Power”]

ON/OFF of phantom power provided at INPUT 7 and 8 (XLR-3-31) can be setup.

<CAUTION!>

Do the following before using the phantom power:

When connecting a condenser microphone to MIC INPUT 7 and 8 (XLR-3-31 type) of the VF160EX, be sure this microphone requires phantom power (+48V).

Switch ON the phantom power after connecting the condenser microphone.

Always mute the VF160EX output when switching ON-OFF the phantom power and when connecting or disconnecting the microphone cable from the VF160EX.

Always switch OFF the phantom power when connecting a dynamic microphone to INPUT 7 and 8 (XLR-3-31 type). Otherwise, a malfunction could occur.

Phantom power cannot be used with the following equipment:

Unbalanced output microphones.

High impedance microphones.

In a microphone where there is voltage leak between pin 2/pin 3 and pin 1 of the microphone cable canon connector.

Old model ribbon microphones of the ground center tap output type.

<CAUTION!>

If the phantom power supply is switched ON, do not connect an unbalanced line dynamic type microphone to INPUT 7 or INPUT 8. Be extremely careful of this as this could damage the internal microphone amplifier of VF160EX.

• Initial setting:

“Off”

• Options:

“On” or “Off”

*You can set the value for each Program individually.

*The settings cannot be saved and loaded as part of the song data.

*The settings are maintained after you turn off the power to the VF160EX.

1.Select “Phantom Power” in the menu selection display and press the [ENTER/YES] key.

The currently set will flash. “Off” will flash in the initial setting.

2.Select the desired item with the [JOG] dial and press the [ENTER/YES] key.

The selected item will be set.

Off (Initial setting)

Phantom power will not be supplied.

 

 

On

Phantom power is supplied to INPUT

 

7 and 8. The PHANTOM LED will be

 

lit.

 

 

3.Press the [EXIT/NO] key (or [STOP] key) to exit from the SETUP mode.

Flashing

147

Page 147
Image 147