System Overview

- System Outline

Paper path

Exit

Fuser

Toner

Cartridge

Dev-Y

 

Dev-M

 

OPC

 

Dev-C

ITB

Dev-K

 

LSU

Cassette

Charging

Conductive Roller charging

Roller resistivity : ~ 10^5 ohm-cm

Applied voltage : -1.1kV

Charge acceptance : -520V

OPC coating thickness : 21um

OPC diameter : 60mm

Non eraser system

1.Organic Photoconductor is charged to uniform voltage by conductive roll charging method

2.No ozone is produced because corona is not used

3.Charger roll is cleaned with cleaning roll

4.Toner remained on OPC after T1 process is cleaned by cleaning blade and retrieved into waste toner box by auger and belt driving mechanism

3-4

Service Manual

Samsung Electronics

 

Page 22
Image 22
Samsung CLP-300 XSG manual System Outline Paper path, Charging