5. DISPLAY

EO1-11155

5.1 LCD Display

5.1 LCD Display

The LCD display adopts 192 x 64 dot LCD display tubes and displays department name, PLU name, item count, transaction name, error message, and so on. Numbers of digits and lines to be required vary depending on the status of the mode lock.

Status of the Mode Lock

REG, MGR, - modes

X, Z modes

SET mode

Description

Department name, PLU name, item count, transaction name, etc. are displayed with up to 16 one-byte or 8 two-byte characters per line in two lines.

Read/Reset menus and titles are displayed with up to 24 one-byte or 12 two-byte characters per line in four lines.

Programming menu and programmed data are displayed with up to 24 one-byte or 12 two-byte characters per line in four lines.

Digit Range for Various Sales Items (“REG”, “MGR”, “ - ”)

PLU Code

(4 digits

in the upper line)

Item Count (11 digits in the upper line)

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Transaction Name (12 digits in the lower line)

Department/PLU Name (16 digits in the lower line)

Error Messages (in any mode except “LOCK”)

When an error occurs, an error message (programmable) is displayed with an error buzzer generated (a long tone).

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Error Message (16 digits x 2 lines)

Read the error message, depress the [C] key to cancel the error status and tone, operate the sequence again after removing the cause of the error.

The following table shows the cause of the error.

If the error status cannot be cancelled or an error message not listed in the table on the next page is displayed, please contact your nearest TOSHIBA TEC representative.