3. READ (X) AND RESET (Z) REPORTS

EO1-11155

3.2 General Notes On Report Takings

(5)Local Batch Status

A local batch status command is sent to the EFT terminal and a response from the EFT terminal is printed out. (condition check)

Example

• Operation: Mode Lock: X for read

When the ECR is being outside a sale and in X mode, depress the [↓] key four times to select “5 EFT(BATCH)”. And depress the [5] or [Enter] key.

Depress the [↓] key to select “2 LOCAL BATCH STATUS”, then depress the [2] or [Enter] key.

TEC STORE

1343 PEACH DRIVE

PHONE: 87-6437

Open 8:00am to 7:00pm Closed: every Wednesday

10-20-2006 FRI #3001

BATCH STATUS

X 9999 ZZZZ9 ZZZZ9 _ZZZZZZ9.99 ZZZZ9 _ZZZZZZ9.99

9999 07:38TM

A B C D E

F G

A:Batch status (0 = Open, C = Closed, P = Pended, X = Incomplete): one character

B:Batch Number: 4 digits

C:Transaction count: 5 digits

D:Item count: 5 digits

E:Batch balance: 7-digit integer + 2-digit decimal

F:Forward transaction count: 5 digits

G:Forward batch balance: 7-digit integer + 2-digit decimal

NOTE:

When no response was sent from the EFT terminal within a specified time (standard: 30 seconds), a timeout error occurs on the ECR and an error message “NO RESPONS” is shown on the LCD display.