Samsung SCX-4100 specifications Periodic Defective Image, Roller Defective image Typical defect

Models: SCX-4100

1 111
Download 111 pages 56.17 Kb
Page 65
Image 65

Alignment & Adjustments

6.9 Periodic Defective Image

If a mark or other printing defect occurs at regular intervals down the page it may be caused by a damaged or contaminated roller. Measure the repetition interval and refer to the table below to identify the roller concerned.

No

1

2

3

4

5

6

7

Roller

Defective image

Typical defect

OPC Drum

75.5mm

white spot on black image or black spot

Charge Roller

37.7mm

black spot

Supply Roller

47.8mm

light or dark horizontal image band

Developing Roller

35.2mm

horizontal image band

Transfer Roller

45.3mm

image ghost

Heat Roller

57.1mm

Black spot and image ghost

Pressure Roller

59.7mm

black spot on the backside

 

 

 

 

L S U

 

Fuser

2

Toner Cartridge

6

 

 

4

3

7

1

 

 

 

PTL

MP Sensor

 

5

 

SCAN PART

1

2

3

4

OPC Drum

Charge Roller

Supply Roller

Developing Roller

5

6

7

Tramsfer Roller

Heat Roller

Pressure Roller

<Rollers Layout>

Service Manual

6-8

Samsung Electronics

Page 65
Image 65