4.5.4 Fusing

The temperature of the heat roller's surface is detected according to the resistance value of the thermistor.

The thermistor resistance is measured using the A/D converter and thus the CPU can determine the temperature of the heat roller. The AC power is controlled by comparing the target temperature to the value from the thermistor. If the value from the thermistor is out of the controlling range while controlling the fusing process, the error stated in the table occurs. (For the domestic model, the Q-PID method has been applied.)

• Heat Lamp Method

Error

Open heat error

Lower heat error

Description

When warming up, it has been lower than 68°C over 28 seconds

Standby:

It has been lower than 80°C over 10 seconds

Printing:

-2 consecutive pages: it has been lower than 145°C over 4 seconds.

-3 consecutive page; it has been 25°C lower

than the fixed fusing temperature over 4 seconds.

LCD Displat

All open heat error are blinking

All low heat error are blinking

Over heat error

It have been higher than 220°C over 3 seconds

All over heat error are blinking

 

 

 

4.5.5 LSU

The LSU consists of the LD (Laser Diode) and the polygon motor control. When the printing signal occurs, the LD is turned on and the polygon motor is enabled. When the light sensor detects the beam, Hsync occurs. When the polygon motor speed becomes a normal, LReady occurs. If these two conditions are satisfied, the status bit of the LSU controller register becomes 1 and the LSU is judged to be ready. If the two conditions are not satisfied, the error shown in the table below occurs.

Error

Description

Polygon motor error

When the polygon motor’s speed doesn’t

 

reach operating speed

 

 

Hsync error

The polygon motor’s speed is normal,

 

but the Hsync signal is not created.

 

 