![](/images/new-backgrounds/1313430/313430179x1.webp)
Callback Settings
●The Callback function is used to forward a callback message to the IP where SmartViewer is in action in case Alarm, Motion Detection, or Video Loss event occurs.
Callback Settings |
|
|
On/Off | On |
|
IP Address | 192.168.001.010 |
|
Port(UDP) | 7900 |
|
Retry | 05 |
|
Transfer Alarm In | Off |
|
Transfer Motion Detection | Off |
|
Transfer Video Loss | Off |
|
Transfer System Log | Off |
|
| OK | Cancel |
●On/Off : Off is default but you may choose On.
●IP Address : IP setting is available only when On is selected from On/off Setting. Select the IP address of PC where SmartViewer is in action.
●Port(UDP) : You may choose one from 7900 to 7999 and the number changes by 1. Selects the Port value for the Callback Connection menu from SmartViewer Setup.
●Retrial : You may choose one from 1 to 20 and the number changes by 1.
●Transfer Alarm In: Set it to On to display alarms on Smart Viewer.
●Transfer Motion Detection: Set it to On to display motion detection events on Smart Viewer.
●Transfer Video Loss: Set it to On to display video loss events on Smart Viewer.
●Transfer System Log: Set it to On to display system logs such as critical system failures.
Caution
-Though Callback is set to ON, any Callback message will be created unless Alarm, Motion Detection, and Video Loss are set by EventRecord.
-Unless the Callback button is clicked, SmartViewer does not receive any Callback message.