Table 1-7. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Error: Incorrect

The DIMM group for CPU n

See "General Memory

memory

is incorrectly configured and

Module Installation

configuration

caused the system to halt.

Guidelines" on page 114 for

CPU n

 

memory configuration

 

information. If the problem

 

 

 

 

persists, see

 

 

"Troubleshooting System

 

 

Memory" on page 150.

!!*** Error:

Remote Access Controller

Ensure that the Remote

Remote Access

initialization failure

Access Controller is properly

Controller

 

installed. See "Installing a

initialization

 

RAC Card" on page 106.

failure *** RAC

 

 

virtual USB

 

 

devices may not

 

 

be available...

 

 

Gate A20 failure Faulty keyboard controller; faulty system board.

General failure The operating system is unable to carry out the command.

See "Getting Help" on page 175.

This message is usually followed by specific information. Note the information, and take the appropriate action to resolve the problem.

HyperTransport

A fatal system error occurred

error caused a

and caused the system to

system reset!

reboot.

Please check the

 

system event log

 

for details!

 

Invalid NVRAM

System detected and

configuration,

corrected a resource conflict.

Resource Re-

 

allocated

 

Check the SEL for information that was logged during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 137 for any faulty components specified in the SEL.

No action is required.

About Your System

37

Page 37
Image 37
Dell R805 Error Incorrect, CPU n, Remote Access, Initialization, Failure *** RAC Virtual USB Devices may not Be available