Table 1-6. LCD Status Messages

Code

Text

Causes

Corrective Actions

 

 

 

 

N/A

SYSTEM NAME

A 62-character string that

This message is for

 

 

can be defined by the user in

information only.

 

 

the System Setup program.

You can change the

 

 

 

 

 

The SYSTEM NAME

system ID and name in

 

 

displays under the following

the System Setup

 

 

conditions:

program. See "Using the

 

 

• The system is powered on. System Setup Program"

 

 

• The power is off and

on page 47.

 

 

 

 

 

active errors are displayed.

 

E1000

FAILSAFE,

Check the system event log

See "Getting Help" on

 

Call Support

for critical failure events.

page 175.

E1114

Temp Ambient

Ambient system

See "Troubleshooting

 

 

temperature is out of

System Cooling

 

 

acceptable range.

Problems" on page 149.

E1118 CPU Temp

The BMC is unable to

Interface

determine the CPU(s)

 

temperature status.

 

Consequently, the BMC

 

increases the CPU fan speed

 

to maximum

 

as a precautionary measure.

Turn off power to the system and restart the system. If the problem persists, see "Getting Help" on page 175.

E1210 CMOS Batt

CMOS battery is missing, or

See "Troubleshooting the

 

the voltage is out of

System Battery" on

 

acceptable range.

page 147.

E1211

ROMB Batt

RAID battery is either

 

 

missing, bad, or unable to

 

 

recharge due to thermal

 

 

issues.

E1214

## PwrGd

Specified voltage regulator

E1216

 

has failed.

 

 

E1217

 

 

Reseat the RAID battery connector. See "RAID Battery" on page 87, and "Troubleshooting System Cooling Problems" on page 149.

See "Getting Help" on page 175.

About Your System

23

Page 23
Image 23
Dell R805 E1000, Call Support, E1114 Temp Ambient, E1118 CPU Temp, Interface, E1210 Cmos Batt, E1211 Romb Batt, E1216