Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1232

VDD 12V PS#

The specified power supply

If removed, reinsert the

 

PwrGd

has failed or has been

power supply into the bay

 

 

removed from the bay while

and reconnect to power.

 

 

the system was on.

For component failures,

 

 

 

see "Getting Help" on

 

 

 

page 175.

E123B LOM Mezz

Voltage regulator for the

PwrGd

LOM daughter card has

 

failed.

Recycle power to the system or clear the SEL. If the problem persists, see "Getting Help" on

page 175.

E123C

Planar LOM

Voltage regulator for the

Recycle power to the

 

PwrGd

integrated LOM has failed.

system or clear the SEL. If

 

 

 

the problem persists, see

 

 

 

"Getting Help" on

 

 

 

page 175.

E1310

RPM Fan ##

RPM of specified cooling

See "Troubleshooting

 

 

fan is out of acceptable

System Cooling

 

 

operating range.

Problems" on page 149.

E1313

Fan

The system is no longer fan-

Check control panel LCD

 

Redundancy

redundant. Another fan

for additional scrolling

 

 

failure will put the system at

messages. See

 

 

risk of over-heating.

"Troubleshooting System

 

 

 

Cooling Problems" on

 

 

 

page 149.

About Your System

25

Page 25
Image 25
Dell R805 owner manual E1232, E123B LOM Mezz, E123C Planar LOM, E1310 RPM Fan ##, E1313 Fan, Redundancy