About Your System 25
E1232 VDD 12V PS#
PwrGd
The specified power supply
has failed or has been
removed from the bay while
the system was on.
If removed, reinsert the
power supply into the bay
and reconnect to power.
For component failures,
see "Getting Help" on
page175.
E123B LOM Mezz
PwrGd
Voltage regulator for the
LOM daughter card has
failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page175.
E123C Planar LOM
PwrGd
Voltage regulator for the
integrated LOM has failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page175.
E1310 RPM Fan ## RPM of specified cooling
fan is out of acceptable
operating range.
See "Troubleshooting
System Cooling
Problems" on page149.
E1313 Fan
Redundancy
The system is no longer fan-
redundant. Another fan
failure will put the system at
risk of over-heating.
Check control panel LCD
for additional scrolling
messages. See
"Troubleshooting System
Cooling Problems" on
page149.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions