Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1811

HDD ## Rbld

The specified hard drive has

See "Troubleshooting a

 

Abrt

experienced a rebuild abort.

Hard Drive" on page 155.

 

 

 

If the problem persists,

 

 

 

see your RAID

 

 

 

documentation.

E1812

HDD ##

The specified hard drive has

Information only.

 

Removed

been removed from the

 

 

 

system.

 

E1914 DRAC5 Conn2

DRAC 5 cable is missing or

Cbl

disconnected.

Reconnect the cable. See "Installing a RAC Card" on page 106.

E1915

IO55 HTSink

Heatsink sensor reports that

See "Getting Help" on

 

Missing

the chipset IO55 heatsink is

page 175.

 

MCP55 Htsink

missing.

 

 

Missing

Heatsink sensor reports that

 

 

 

the chipset MCP heatsink

 

 

 

heatsink is missing.

 

E1A12

PCI Rsr

One or all of the PCIe risers

Reinstall the missing riser

 

Missing

is missing, preventing the

card(s).

 

 

system from powering on.

 

E1A14 SAS Cable A SAS cable A is missing or bad.

Reseat the cable. If the problem persists, replace cable. See "SAS Controller Daughter Card" on page 84.

E1A15 SAS Cable B SAS cable B is missing or bad.

Reseat the cable. If the problem persists, replace cable. See "SAS Controller Daughter Card" on page 84.

E1A1C LOM Mezz

LOM daughter card is

Install or reseat the LOM

Missing

missing.

daughter card. If the

 

 

problem persists, replace

 

 

the card. See "Getting

 

 

Help" on page 175.

30

About Your System

Page 30
Image 30
Dell R805 E1811 HDD ## Rbld, Abrt, E1812 HDD ##, Removed, E1914 DRAC5 Conn2, Cbl, E1915 IO55 HTSink, Missing, MCP55 Htsink