Table 1-7. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

ROM bad checksum

Expansion card improperly

Reseat the expansion card(s).

= address

installed or faulty.

Ensure that all appropriate

 

 

cables are securely connected

 

 

to the expansion card(s). If

 

 

the problem persists, see

 

 

"Troubleshooting Expansion

 

 

Cards" on page 158.

Sector not found

Faulty hard drive, USB

See "Troubleshooting a USB

Seek error

device, or. USB medium.

Device" on page 143 or

 

"Troubleshooting a Hard

Seek operation

 

 

Drive" on page 155 for the

failed

 

 

appropriate drive(s) installed

 

 

 

 

in your system.

Shutdown failure

Shutdown test failure.

See "Troubleshooting System

 

 

Memory" on page 150.

The amount of

Memory has been added or

system memory has

removed or a memory

changed

module may be faulty.

This system

Microprocessor(s) is not

supports only

supported by the system.

Opteron(TM) 2000

 

series

 

processors.

 

Time-of-day

Faulty battery or faulty chip.

clock stopped

 

If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 150.

Install a supported microprocessor or microprocessor combination. See "Installing a Processor" on page 123.

See "Troubleshooting the System Battery" on page 147.