Table 1-7. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

PCIe Training

Faulty or improperly installed

Reseat the PCIe card in the

Error: Slot n

PCIe card in the specified

specified slot number. See

 

slot.

"Expansion Cards" on

 

 

page 91. If the problem

 

 

persists, see "Getting Help"

 

 

on page 175.

Plug & Play

Error encountered in

Configuration

initializing PCIe device;

Error

faulty system board.

Install the NVRAM_CLR jumper and reboot the system. See Figure 6-1 for jumper location. If the problem persists, see "Troubleshooting Expansion Cards" on page 158.

Read fault

Requested sector not found

Remote Access Controller cable error or incorrect card in the RAC slot.

The operating system cannot read from the hard drive or USB device, the system could not find a particular sector on the disk, or the requested sector is defective.

RAC cables not connected, or RAC card installed in wrong expansion slot.

Replace the USB medium or device. Ensure that the USB or hard drive cables are properly connected. See "Troubleshooting a USB Device" on page 143, or "Troubleshooting a Hard Drive" on page 155 for the appropriate drive(s) installed in your system.

Check that the RAC cables are connected, and that the RAC card is installed in the correct expansion slot. See "Installing a RAC Card" on page 106.

Remote

System unable to process

Retry Remote Configuration.

configuration

Remote Configuration

 

update attempt

request

 

failed

 

 

About Your System

41

Page 41
Image 41
Dell R805 owner manual Error Slot n, Plug & Play, Remote, Update attempt, Failed