Table 1-7. System Messages

Message

Causes

Corrective Actions

 

 

 

Alert! Node

The memory configuration

Ensure that the memory

Interleaving

does not support node

modules are installed in a

disabled! Memory

interleaving, or the

configuration that supports

configuration

configuration has changed

node interleaving. Check

does not support

(for example, a failed

other system messages for

Node

DIMM) so that node

additional information for

Interleaving.

interleaving cannot be

possible causes. For memory

 

supported. The system will

configuration information,

 

run but with reduced

see "General Memory

 

functionality.

Module Installation

 

 

Guidelines" on page 114. If

 

 

the problem persists, see

 

 

"Troubleshooting System

 

 

Memory" on page 150.

Attempting to

Remote Configuration

update Remote

request has been detected

Configuration.

and is being processed.

Please wait...

 

BIOS Update

Remote BIOS update

Attempt Failed!

attempt failed.

Caution!

NVRAM_CLR jumper is

NVRAM_CLR jumper

installed. CMOS has been

is installed on

cleared.

system board.

 

Wait until the process is complete.

Retry the BIOS update. If problem persists, see "Getting Help" on page 175.

Remove NVRAM_CLR jumper. See Figure 6-1 for jumper location.

CPUs with

Microprocessors with

Ensure that all

different cache

different cache sizes are

microprocessors have the

sizes detected!

installed.

same cache size and that

 

 

they are properly installed.

 

 

See "Processors" on page 120.

Decreasing

Faulty or improperly installed

See "Troubleshooting System

available memory

memory modules.

Memory" on page 150.

36

About Your System

Page 36
Image 36