Chapter 1 - Installation
1.4Other Precautions
Do not carry the inverter by the front cover.
Do not install the inverter in a location where excessive vibration is present. Be cautious when installing on presses or moving equipment.
The life span of the inverter is greatly affected by the ambient temperature. Install in a location where temperature are within permissible limits (- 10 ~ 40 ℃).
The inverter operates at
Do not install the inverter in a location where oil mist, combustible gas, or dust is present. Install the inverter in a clean location or in an enclosed panel, free of foreign substance.
When installing the inverter inside a panel with multiple inverters or a ventilation fan, use caution. If installed incorrectly, the ambient temperature may exceed specified limits.
Panel | Panel | Ventilating fan |
|
| Inverter |
|
|
Inverter Inverter |
|
|
|
Cooling fan | Inverter |
|
|
|
|
| |
GOOD (O) | BAD (X) | GOOD (O) | BAD (X) |
[When installing several inverters in a panel] | [When installing a ventilating fan in a panel] |
Install the inverter using screws or bolts to insure the inverter is firmly fastened.