Chapter 2 - Operation

2.4 Operation Method

The ACtionMaster has several operation methods as shown below.

Operation Method

Function

Function Setting

Operation using Keypad

Run/Stop command and frequency are set only through the

DRV 03: Keypad

 

keypad.

DRV 04: Keypad-1 or -2

Operation using

Closing FX or RX terminal performs Run/Stop.

DRV 03: Fx/Rx-1 or -2

Control Terminals

Frequency reference is set through V1 or I or V1+I terminal.

DRV 04: V1 or I or V1+I

Operation using both

Run/Stop is performed by the keypad.

DRV 03: Keypad-1 or -2

Keypad and Control

Frequency reference is set through the V1 or I or V1+I

DRV 04: V1 or I or V1+I

Terminals

terminal.

 

 

Closing FX or RX terminal performs Run/Stop.

DRV 03: Fx/Rx-1 or -2

 

Frequency reference is set through the keypad.

DRV 04: Keypad-1 or -2

Operation using

Operation using option board.

Please refer to ‘Chapter 7 -

Option Boards

The ACtionMaster has five option boards and three sub-

Options’ for more

 

boards.

information.

 

Option Boards: RS485, Device-Net, F-Net, ProfiBus and

 

 

ModBus

 

 

Sub-Boards:Sub-A Board, Sub-B Board, Sub-C Board and

 

 

Sub-D Board.

 