CHAPTER 7 - OPTIONS

The ACtionMaster series inverter provides many options for various applications. See the following option table and select the proper options according to your application.

Option

Sub Boards

Internal Installation

Option

Boards

External Installati on

Keypad

 

Name

Description

 

Extended I/O Module

Sub-A Board

Three Multi-Function Inputs (P4, P5, P6)

Three Multi-Function Outputs (Q1, Q2, Q3)

(Extended I/O)

Auxiliary Analog Frequency Reference (V2)

 

 

LM (Load Meter) Output (0 ~ 10V)

Sub-B Board

Encoder Pulse Input – Speed Feedback (AOC, BOC / A+, A-, B+, B-)

Encoder Pulse Output (FBA, FBB)

(Speed Feedback)

Vector control (PG operation) and reference freq via pulse input

 

 

Extended I/O Module

Sub-C Board

Three Multi-Function Inputs (P4, P5, P6)

One Multi-Function Outputs (Q1)

(Extended I/O)

Isolated Auxiliary Analog Frequency Reference (V2)

 

 

Two Isolated Analog Meter Output (AM1, AM2)

 

Extended I/O Module

Sub-D Board

Three Multi-Function Inputs (P4, P5, P6)

Two Multi-Function Outputs (Q1, Q2)

(Extended I/O, Speed

Auxiliary Analog Frequency Reference (V2)

Feedback)

Encoder Pulse Input – Speed Feedback (AOC, BOC / A+, A-, B+, B-)

 

 

Encoder Pulse Output (FBA, FBB)

 

Embedded DeviceNet protocol

 

CAN Controller

Device Net

Inverter Connection: Max. 64

Input Voltage: DC 11 ~ 25V

 

 

Baud Rate: 125, 250, 500k bps

 

CSMA/CD-NBA Method

 

Connection with Fnet Communication Module for GLOFA PLC

PLC Communication

Inverter Connection: Max. 64

(F-Net)

Baud Rate: 1M bps

 

Token Method

 

RS-485 Communic ation

RS-485

Inverter Connection: Max. 32

 

Baud Rate: Max. 19200 bps

 

Connection to ProfiBus Network

Profi-Bus

Device Type: Profibus DP Slave

Inverter Connection: Max. 64

 

 

Baud Rate: Max. 12M bps

LCD

32-Character Display

Download and Upload from the Keypad

 

7-Segment

Six Digit 7-Sengment Display

7-1

Page 163
Image 163
HP 30 30 manual Option, Name Description