Chapter 8 - Troubleshooting & Maintenance

Protective

 

Cause

 

Remedy

Function

 

 

 

 

 

 

 

 

 

correctly.

 

2)

Incorrect encoder parameter setting

2)

Check parameters of EXT-14,15,16 are set correctly.

 

3)

Sub-B board or Encoder fault

3)

Replace the faulty Sub-B board or Encoder to a new

 

 

 

one.

Option Fault

Faulty option connector connection

Check option connection.

 

1)

Wdog error (CPU fault)

Replace inverter

H/W Fault

2)

EEP error (memory fault)

 

 

 

3)

ADC Offset (current feedback circuit fault)

 

 

Communication

1)

Faulty connection between inverter and keypad

1)

Check connector

Fault

2)

Inverter CPU malfunction

2)

Replace inverter

Operating

LOP (Loss of reference from the Option),

Eliminate cause of fault

Method when the

LOR (Remote)

 

 

Speed

LOV (V1),

 

 

Reference is

LOI (I),

 

 

Lost

LOX (Sub-V2, ENC)

 

 

Inverter

1)

Load is larger than inverter rating

1)

Increase motor and/or inverter capacity

Overload

2)

Selected incorrect inverter capacity

2)

Select correct inverter capacity

Magnetic

1)

Damaged M/C operation detection contact

1)

Check M/C operation detection contact is working

 

 

properly.

contactor fault

 

 

2)

M/C malfunction

2)

Check M/C is working properly. Replace it, if needed.

 