3.3.1Frequency set by External Source and Run/Stop by Keypad

1.Install a potentiometer on terminals V1, VR, 5G and connect wiring as shown below left.

When a ‘4 to 20mA’ current source is used as the frequency reference, use terminals I and 5G as shown below right.

DRV 04 must be set at V1.

1 , 1/2 W

P1 P2 P3 FX RX NC VR VI

JOG CM CM BX RST I FM 5G

DRV 04 must be set at I.

P1 P2 P3 FX RX NC VR VI

JOG CM CM BX RST I FM 5G

4 to 20mA signal

2.Apply AC power.

3.LCD: Press [] key to move DRV 03.

7-Seg:Rotate encoder knob until ‘03’ is displayed.

4.LCD: Press [PROG] key.

7-Seg: Press [PROG/ENT] key.

5.LCD: Press [] key one time.

7-Seg:Rotate encoder knob and set at ‘0’.

6.LCD: Press [ENT] key.

7-Seg: Press [PROG/ENT] key.

7.Confirm that the DRV 04 is set at ‘V1’.

DRV►T/K

0.0 A

00 STP

0.00Hz

 

 

DRV► Drive mode

03 Fx/Rx-1

DRV► Drive mode

03 Fx/Rx-1

DRV► Drive mode

03 Keypad

DRV► Drive mode

03 Keypad

DRV► Freq mode

04 V1

The DRV LED is ON.

The PROG/ENT LED is turned ON.

The PROG/ENT LED is turned ON.

The PROG/ENT LED is turned OFF.

The PROG/ENT LED is turned ON.

8.Press [SHIFT/ESC] key.

Set the frequency by rotating the potentiometer.

9.LCD: Press [FWD] or [REV] key.

7-Seg: Press [RUN] key.

DRV►T/V

0.0 A

00 STP

60.00Hz

 

 

The FWD or REV LED starts blinking.

The RUN LED starts blinking. To change the motor running direction, change DRV 13 to ‘1’.