Chapter 6 - Parameter Description [I/O]

[Auto-A]

 

 

 

 

Output Frequency

 

 

 

 

 

 

 

 

 

This mode will allow the inverter to operate automatically

 

 

 

 

 

 

 

 

 

followed by its pre-programmed sequence. According to

 

 

 

Sequence 1

 

Sequence 3

Sequence 2

 

 

this sequence, eight different steps of Frequency,

 

SEQ1 / 2F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transient Time, Steady Speed time and Motor Direction

SEQ2 / 2F

 

 

 

 

 

 

 

 

 

 

 

 

 

can be initiated with only a single multi-function input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

contact closure (I/O-12 ~ I/O-14). The sequence and steps

SEQ1 / 1F

 

 

 

 

 

 

 

 

 

 

 

 

 

are set in I/O-51 ~ I/O-84.

 

 

 

SEQ3 / 2F

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step

Parameter

Speed-H

Speed-M

Speed-L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Code

(P3)

(P2)

(P1)

SEQ3 / 1F

 

 

 

 

 

 

 

 

 

 

 

 

 

Sequence 1

 

0

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sequence 2

I/O-50 ~

0

1

0

P1-CM

 

 

 

 

 

 

 

 

 

 

 

 

 

Sequence 3

I/O-84

1

0

0

‘SEQ-L’

 

 

ON

 

 

 

 

 

 

 

 

Time

Sequence 4

0

1

1

P2-CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sequence 5

 

1

0

1

‘SEQ-M’

 

 

 

 

 

 

ON

 

 

 

Time

0: OFF, 1: ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Example 2 of ‘Auto-A’ operation]

 

 

 

 

 

 

 

 

 

 

 

 

[AUTO B]

 

 

 

 

 

 

 

 

 

 

 

This mode can be also used to program up to 8 different

Output Frequency

 

 

 

 

 

 

steps as Auto A. However, to switch from one step to

 

 

2D

 

 

 

another, an external contact closure set to ‘Go step’ is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

required.

 

 

 

Seq1 / 2F

 

 

 

(Forward)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1D

 

 

 

 

 

Output Frequency

 

 

Seq1 / 1F

(Forward)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sequence 1

Sequence 3

Sequence 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

SEQ1 / 2F

 

 

 

 

 

 

 

 

 

 

SEQ2 / 2F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3D

 

SEQ1 / 1F

 

 

 

Seq1 / 3F

 

 

 

 

 

(Reverse)

 

SEQ3 / 2F

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

1T

1S

2T

2S

3T

3S

 

 

 

 

 

P1-CM

ON

 

 

 

 

 

 

SEQ3 / 1F

 

 

 

‘SEQ-L’

 

 

 

 

 

Time

 

 

 

 

 

[Example 1 of ‘Auto-A’ operation]

 

P1-CM

ON

 

 

 

 

‘SEQ-L’

 

Time

 

 

 

 

 

 

 

 

 

 

 

P2-CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‘SEQ-M’

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P3-CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‘Go step’

 

ON

 

ON

 

 

ON

 

 

 

ON

 

 

 

ON

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

100msec

 

 

 

 

 

 

 

 

 

 

 

 

 

[Example of ‘Auto-B’ operation]

6-50

Page 142
Image 142
HP 30 30 manual Parameter Description I/O Auto-A, Auto B