Chapter 6 - Parameter Description [FU2]

This function is used to allow the inverter to reset itself for a selected number of times after a fault has occurred. The inverter can restart itself automatically when a fault occurs. To use the speed search function during auto restarting set FU2-22 to ‘xx1x’. See FU2-22 ~ FU2-25.

When an under voltage (LV) fault, inverter disable (BX) or Arm short occurs, the drive does not restart automatically.

Output Frequency

 

t: FU2-27

t

t

 

Time

1st Fault

2nd Fault

Restart with

Restart with

Speed Search Speed Search

Note: Inverter decreases the retry number by one as a fault occurs. When restarted without a fault during 30 seconds, the inverter increases the retry number by one.

FU2-28: Speed search hold time

FU2► SS blk time

 

 

28

 

1.0

 

28

1.0 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

1.0 sec

 

 

1. 0

 

 

 

 

 

 

 

 

 

 

The inverter starts speed search function after the preset time t1 elapses. Set the desired time for inverter to restart the previous operation using Speed search function.

Speed search function [FU2-22] is activated automatically during exchanging function.

 

Code

 

Keypad

 

Description

 

Factory

 

Setting

 

 

display

 

 

setting

 

Range

 

 

 

 

 

 

 

 

 

 

 

 

Speed search

 

 

 

 

 

FU2-28

SS blk time

 

hold time

 

1 sec

0 ~ 60

 

 

during speed

 

 

sec

 

 

 

 

 

 

 

 

 

 

 

 

 

search

 

 

 

 

Input power[v]

Time [sec]

Motor speed [rpm]

Output vtg [V]

Time [sec]

t1 t2 t3

Time [sec]

t1 : Ssearch wait time

t2 : Ssearch Accel time

t3 : Ssearch Decel time

Note: This parameter is not valid when low voltage (LV) fault or instant power loss (within 15msec) occurs.

FU2-30: Rated Motor Selection

FU2-31: Number of Motor Pole

FU2-32: Rated Motor Slip

FU2-33: Rated Motor Current

FU2-34: No Load Motor Current

FU2-36: Motor Efficiency

FU2-37: Load Inertia

If you do not set these values, inverter will use its default values.

FU2►Motor select

 

 

30

 

0

 

30

0.75kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

0.75 kW

 

 

0

 

(This value is set according to the model number before shipping)

This parameter sets the motor capacity. Other motor related parameters are changed automatically according to