Chapter 6 - Parameter description [FU1]

Note: The set value is the percentage of FU2-33 [Rated Motor Current].

FU1-59 [Stall Prevention Mode Selection]

Setting Range

FU1-59

Description

3rd bit

2nd bit

1st bit

0

0

1

001

Stall Prevention during

Acceleration

 

 

 

 

0

1

0

010

Stall Prevention during Steady

Speed

 

 

 

 

1

0

0

100

Stall Prevention during

Deceleration

 

 

 

 

When FU1-59 is set to ‘111’, stall prevention works during accelerating, steady speed and decelerating.

Note: The acceleration and deceleration time may take longer than the time set in DRV-01, DRV-02 when Stall Prevention is selected.

Note: If stall prevention status persists, inverter may stop during acceleration.

Related Functions: FU2-33 [Rated Motor Current]

Output Current

FU1-60 [Stall Level]

Time

FU1-60 [Stall level]

Output Frequency

[Stall Prevention during Acceleration]

Time

Output Current

FU1-60 [Stall Level]

Time

FU1-60 [Stall Level]

Output Frequency

Time

[Stall Prevention during Steady Speed]

DC Link Voltage

390VDC or 680V DC

Time Output Frequency

Time

[Stall Prevention during Deceleration]

FU1-99: Return Code (7-Segment Keypad)

990

Factory Default:

0

 

 

This code is used to exit a group when using a 7-segment keypad. After pressing PROG/ENT key, set the value to ‘1’ and press the PROG/ENT key again to exit.

Related Functions: FU2-99 [Return Code]

I/O-99 [Return Code]

EXT-99 [Return Code]

COM-99 [Return Code]

6-20