HP 30 30 manual DRV-01 Acceleration Time, Parameter Description DRV, Acc. time, 10.0 sec

Models: 30 30

1 218
Download 218 pages 18.86 Kb
Page 86
Image 86

Chapter 6 - Parameter Description [DRV]

 

Code

 

Keypad Display

 

Parameter Name

 

 

 

 

 

 

 

I/O-01

 

V1 filter

 

Filter Time Constant for

 

 

 

V1 Signal Input

 

 

 

 

 

 

 

 

 

 

 

 

I/O-02

 

V1 volt x1

 

V1 Input

 

 

 

Minimum Voltage

 

 

 

 

 

 

 

 

 

 

Frequency

 

I/O-03

 

V1 freq y1

 

Corresponding to V1

 

 

 

 

 

Input Minimum Voltage

 

 

 

 

 

 

 

I/O-04

 

V1 volt x2

 

V1 Input Maximum

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

Frequency Corresponding

 

I/O-05

 

V1 freq y2

 

to V1 Input Maximum

 

 

 

 

 

Voltage

Important : Increase I/O-01-[Filter Time Constant for V1 Signal Input] if the V1 signal is affected by noise causing unstable operation. Increasing this value makes response time slower.

Set freq.

I/O-05

I/O-03

V1 analog input (0~10V)

I/O-02

I/O-04

V1 Minimum V

V1 Maximum V

I/O-06~10 [ Analog Current Input “ I “ Signal adjustment ]

Command Freq/Torque setting via “I” input terminal when set DRV-04 [Frequency/Torque mode] to 3 (I) or 4 (V1+I)

Code

Default setting

Setting range

I/O-06

10 [msec]

0 ~ 10000 [msec]

I/O-07

4 [mA]

0 ~ 20 [mA]

I/O-08

0 [Hz]

0 ~ Max. freq

I/O-09

20 [mA]

0 ~ 20 [mA]

I/O-10

60 [Hz]

0 ~ Max. freq

 

Code

 

Keypad display

 

Parameter Name

 

I/O-06

 

I filter

 

Filter time constant for I signal

 

 

 

Input

 

 

 

 

 

 

I/O-07

 

I curr x1

 

I Input Minimum Current

 

I/O-08

 

I freq y1

 

Frequency Corresponding to I

 

 

 

Input Minimum Current

 

 

 

 

 

 

I/O-09

 

I curr x2

 

I Input Maximum Current

 

I/O-10

 

I freq y2

 

Frequency Corresponding to I

 

 

 

Input Maximum Current

 

 

 

 

 

Important : Increase I/O-06-[Filter time constant for I signal Input] if the I signal is affected by noise causing unstable operation. Increasing this value makes response time slower.

Set freq

I/O-10

I/O-08

Terminal I ( 0 ~ 20 mA )

I/O-07

I/O-09

I Minimum

I Maximum

current

current

Related parameters : DRV-04 [Frequency or Torque Mode] DRV-16 [Speed Unit Selection] FU1-20 [Maximum Frequency] FU2-39 [Control Mode Selection] I/O-1~10 [Analog Frequency command/Torque]

DRV-01: Acceleration Time

DRV►

Acc. time

 

 

01

 

10.0

 

01

10.0 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

10.0 sec

 

 

10.0

 

 

 

 

 

 

 

 

 

 

6-2