Chapter 6 - Parameter description [I/O]

6.4Input/Output Group [I/O] I/O-00: Jump to Desired Code #

I/O► Jump code

001

Factory Default:

1

 

 

Jumping directly to any parameter code can be accomplished by entering the desired code number. This code is available only with LCD keypad.

I/O-01 ~ I/O-05: Analog Voltage Input (V1) Signal Adjustment

I/O► V1 volt x2

 

 

04

 

10.00

 

04

0.00 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

10.00 V

 

 

10.00

 

This is the maximum voltage of the V1 input at which inverter outputs maximum frequency.

I/O►

V1 volt y2

 

 

05

 

60.00

 

05

60.00 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

60.00 Hz

 

 

60.00

 

This is the inverter output maximum frequency when there is the maximum voltage (I/O-03) on the V1 terminal.

This is used to adjust the analog voltage input signal when the frequency is referenced by the control terminal ‘V1’. This function is applied when DRV-04 is set to ‘V1’ or ‘V1+I’. Reference frequency versus Analog voltage input curve can be made by four parameters of I/O-02 ~ I/O-04.

I/O► V1 filter

 

01

 

10

 

01

10 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

10 ms

 

 

10

 

Reference Frequency

I/O-05

 

I/O-03

 

I/O-02

I/O-04

Analog Voltage Input (V1)

This is the filtering time constant for V1 signal input. Increase this value if the V1 signal is affected by noise causing unstable operation of the inverter. Increasing this value makes response time slower.

I/O► V1 volt x1

 

02

 

0.00

 

02

0.00 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

0.00 V

 

 

0.00

 

This is the minimum voltage of the V1 input at which inverter outputs minimum frequency.

I/O► V1 volt y1

 

 

03

 

0.00

 

03

0.00 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

0.00 Hz

 

 

0.00

 

This is the inverter output minimum frequency when there is the minimum voltage (I/O-02) on the V1 terminal.

[Reference Frequency vs. Analog Voltage Input, V1 (0 to 10V)]

Related Functions: DRV-04 [Frequency Mode] FU1-20 [Maximum Frequency]

I/O-06 ~ I/O-10: Analog Current Input (I) Signal Adjustment

This is used to adjust the analog current input signal when the terminal ‘I’ references the frequency. This function is applied when DRV-04 is set to ‘V1’ or V1+I’. Reference frequency versus Analog current input curve can be made by four parameters of I/O-07 ~ I/O-10.

I/O► I filter

 

06

 

10

 

06

10 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

10 ms

 

 

10

 

6-35

Page 127
Image 127
HP 30 30 manual Input/Output Group I/O I/O-00 Jump to Desired Code #, 01 ~ I/O-05 Analog Voltage Input V1 Signal Adjustment