Chapter 5 - Parameter List

Code

Description

Keypad Display

Setting Range

Units

Factory

Adj.

Page

LCD

 

7-Segment

LCD

 

7-Segment

Default

During

 

 

 

 

 

Run

 

EXT-56

Torque Detection Level

TD Level

50

0 to 150 [%]

0.1

100 [%]

Yes

 

EXT-57

Torque Detection

TD Band

51

0 to 10 [%]

0.1

5 [%]

Yes

 

Bandwidth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not

 

 

 

 

[PROG/ENT]

 

 

 

 

EXT-99

Return Code

99

Not available

 

or

-

1

Yes

 

displayed

 

 

 

 

 

 

 

 

[SHIFT/ESC]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.6 Communication Group [COM]

COM group appears only when the corresponding Option Boards are installed. Please refer to the option manual for detail.

Code

Description

Keypad Display

Setting Range

Units

Factory

Adj.

Page

LCD

 

7-Segment

LCD

 

7-Segment

Default

During

 

 

 

 

 

Run

 

COM-00

Jump to Desired Code #

Jump code

 

Not displayed

0 to 99

 

Not available

1

1

Yes

 

 

 

 

 

 

None

0

 

 

 

 

 

 

 

 

 

Device Net

1

 

 

 

 

 

 

 

 

 

Synchro

2

 

 

 

 

COM-01

Option Board Type

Opt B/D

01

PLC-GF

3

-

None

Yes

 

Profibus-DP

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital-In

5

 

 

 

 

 

 

 

 

 

RS485

6

 

 

 

 

 

 

 

 

 

Modbus-RTU

7

 

 

 

 

 

 

 

 

 

None

0

 

 

 

 

COM-02

Option Mode

Opt Mode

02

Command

1

-

None

No

 

Freq

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cmd + Freq

3

 

 

 

 

COM-03

Option Version

Opt Version

03

-

-

-

-

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 Bit Bin

0

 

 

 

 

 

 

 

 

 

8 BCD 1%

1

 

 

 

 

 

Binary Option Input

 

 

 

8 BCD 1Hz

2

 

 

 

 

COM-04

D-In Mode

04

12 Bit Bin

3

-

8 Bit Bin

No

 

Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 BCD 0.1%

4

 

 

 

 

 

 

 

 

 

12 BCD 0.1Hz

5

 

 

 

 

 

 

 

 

 

12 BCD 1Hz

6

 

 

 

 

COM-05

Binary Input Filter Value

Digital Ftr

05

2-50

 

 

1

15

Yes

 

COM-10

Device Net ID

MAC ID

10

0-63

 

 

1

0

Yes

 

 

Device Net

 

 

 

125 kbps

0

 

 

 

 

COM-11

Baud Rate

11

250 kbps

1

-

125 kbps

Yes

 

Communication Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500 kbps

2

 

 

 

 

COM-12

Device Net Output

Out Instance

12

20

0

-

20

No

 

 

Instance

 

 

 

21

1

 

 

 

 

 

 

 

 

 

100

2

 

 

 

 

5-18

Page 78
Image 78