Chapter 3 - Quick-Start Procedures

3.3.2Frequency set by Keypad and Run/Stop by External Source.

1. Connect wiring as shown below.

LCD Display

7-Segment Display

P1 P2 P3 FX RX NC VR VI

JOG CM

CM BX

RST

I

FM 5G

2.Apply AC power.

3.Confirm that the DRV 03 is set at ‘Fx/Rx-1’.

4.Confirm that the DRV 04 is set at ‘Keypad-1’.

5.Press [SHIFT/ESC] key.

DRV►T/K

0.0 A

00 STP

0.00Hz

 

 

DRV► Drive mode

03 Fx/Rx-1

DRV► Freq mode

04 Keypad-1

DRV►T/K

0.0 A

00 STP

0.00Hz

 

 

The DRV LED is ON.

6.LCD: Press [PROG] key.

7-Seg: Press [PROG/ENT] key.

7.LCD: Set the frequency using [SHIFT/ESC] and [] key.

7-Seg:Set the frequency by rotating the encoder knob.

DRV► Cmd. freq

00 0.00Hz

DRV► Cmd. freq

00 60.00Hz

The PROG/ENT LED is turned ON.

The PROG/ENT LED is turned ON.

8. LCD: Press [ENT] key to save the data.

DRV►T/V

0.0 A

7-Seg:Press [PROG/ENT] key to save the data.

00 STP

60.00Hz

9.Close the FX or RX contact to run the motor.

10.Open the FX or RX contact to stop the motor.

The FWD or REV LED starts blinking.

The STOP/RESET LED starts blinking.

The RUN LED starts blinking.

The STOP/RESET LED starts blinking.

3-5