HP 30 30 manual Function 1 Group FU1

Models: 30 30

1 218
Download 218 pages 18.86 Kb
Page 63
Image 63

Chapter 5 - Parameter List

5.2 Function 1 Group [FU1]

 

 

Keypad Display

Setting Range

 

 

Factory

Adj.

 

Code

Description

 

Units

During

Page

LCD

 

7-Segment

LCD

 

7-Segment

Default

 

 

 

 

 

Run

 

 

 

 

 

 

 

 

FU1-00

Jump to Desired Code #

Jump code

 

Not displayed

1 to 60

 

Not available

1

1

Yes

6-2

 

 

 

 

 

None

 

 

0

 

 

 

 

FU1-03

Run Prevention

Run Prev.

03

Forward Prev

 

 

1

-

None

No

6-2

 

 

 

 

 

Reverse Prev

 

 

2

 

 

 

 

 

 

 

 

 

Linear

 

 

0

 

 

 

 

 

 

 

 

 

S-curve

 

 

1

 

 

 

 

FU1-05

Acceleration Pattern

Acc. pattern

05

U-curve

 

 

2

-

Linear

No

6-2

 

 

 

 

 

Minimum

 

 

3

 

 

 

 

 

 

 

 

 

Optimum

 

 

4

 

 

 

 

 

 

 

 

 

Linear

 

 

0

 

 

 

 

 

 

 

 

 

S-curve

 

 

1

 

 

 

 

FU1-06

Deceleration Pattern

Dec. pattern

06

U-curve

 

 

2

-

Linear

No

6-2

 

 

 

 

 

Minimum

 

 

3

 

 

 

 

 

 

 

 

 

Optimum

 

 

4

 

 

 

 

 

 

 

 

 

Decel

 

 

0

 

 

 

 

FU1-07

Stop Mode

Stop mode

07

DC-brake

 

 

1

-

Decel

No

6-2

 

 

 

 

 

Free-run

 

 

2

 

 

 

 

FU1-0813

DC Injection Braking

DcBr freq

08

FU1-22 to 60 [Hz]

 

0.01

5.00 [Hz]

No

 

 

Frequency

 

 

 

 

 

 

 

 

 

 

 

FU1-09

DC Injection Braking

DcBlk time

09

0 to 60 [sec]

 

0.01

0.1 [sec]

No

 

On-delay Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-2

FU1-10

DC Injection Braking

DcBr value

10

0 to 200 [%]

 

1

50 [%]

No

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU1-11

DC Injection Braking

DcBr time

11

0 to 60 [sec]

 

0.1

1.0 [sec]

No

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU1-12

Starting DC Injection

DcSt value

12

0 to 200 [%]

 

1

50 [%]

No

 

Braking Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-2

FU1-13

Starting DC Injection

DcSt time

13

0 to 60 [sec]

 

0.1

0.0 [sec]

No

 

 

Braking Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU1-14

Pre-excitation Time

PreExTime

14

0 to 60 [sec]

 

0.1

1.0 [sec]

No

6-2

FU1-15

Hold Time

Hold Time

15

0 to 1000 [ms]

 

1

1000 [ms]

No

6-2

FU1-16

Pre-excitation Current

Flux Force

16

100 to 500 [%]

 

0.1

100.0 [%]

No

6-2

FU1-20

Maximum Frequency

Max freq

20

40 to 400 [Hz]

 

0.01

60.00 [Hz]

No

 

FU1-21

Base Frequency

Base freq

21

30 to FU1-20

 

0.01

60.00 [Hz]

No

6-2

FU1-22

Starting Frequency

Start freq

22

0.01 to 60 [Hz]

 

0.01

0.50 [Hz]

No

 

FU1-23

Frequency Limit selection

Freq limit

23

No

 

 

0

-

No

No

6-2

Yes

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

FU1-2414

Low Limit Frequency

F-limit Lo

24

FU1-22 to FU1-25

 

0.01

0.50 [Hz]

No

 

13Code FU1-08 through FU1-11 appears only when FU1-07 is set to ‘DC-Brake’.

14Code FU1-24 through FU1-25 appears only when FU1-23 is set to ‘Yes’.

5-3

Page 63
Image 63
HP 30 30 manual Function 1 Group FU1