Chapter 5 - Parameter List

5.3 Function 2 Group [FU2]

Code

Description

Keypad Display

Setting Range

 

Units

Factory

Adj.

Page

LCD

 

7-Segment

LCD

 

7-Segment

Default

During

 

 

 

 

 

Run

 

FU2-00

Jump to desired code #

Jump code

 

Not displayed

1 to 94

 

Not available

1

1

Yes

6-2

FU2-01

Previous Fault History 1

Last trip-1

01

By pressing [PROG] and [▲] key,

 

 

 

 

FU2-02

Previous Fault History 2

Last trip-2

02

 

 

 

 

the frequency, current, and

 

 

 

 

FU2-03

Previous Fault History 3

Last trip-3

03

-

None

-

 

operational status at the time of fault

 

FU2-04

Previous Fault History 4

Last trip-4

04

 

 

 

6-2

can be seen.

 

 

 

 

FU2-05

Previous Fault History 5

Last trip-5

05

 

 

 

 

 

 

 

 

 

 

 

 

 

FU2-06

Erase Fault History

Erase trips

06

No

 

 

0

-

No

Yes

 

Yes

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

FU2-07

Dwell Frequency

Dwell freq

07

FU1-22 to FU1-20

 

0.01

5.00 [Hz]

No

6-2

FU2-08

Dwell Time

Dwell time

08

0 to 10 [sec]

 

0.1

0.0 [sec]

No

 

 

FU2-10

Frequency Jump

Jump freq

10

No

 

 

0

-

No

No

 

Selection

Yes

 

 

1

 

 

 

 

 

FU2-1117

Jump Frequency 1 Low

Jump lo 1

11

FU1-22 to FU2-12

 

0.01

10.00 [Hz]

No

 

FU2-12

Jump Frequency 1 High

Jump Hi 1

12

FU2-11 to FU1-20

 

0.01

15.00 [Hz]

No

6-2

FU2-13

Jump Frequency 2 Low

Jump lo 2

13

FU1-22 to FU2-14

 

0.01

20.00 [Hz]

No

 

 

FU2-14

Jump Frequency 2 High

Jump Hi 2

14

FU2-13 to FU1-20

 

0.01

25.00 [Hz]

No

 

FU2-15

Jump Frequency 3 Low

Jump lo 3

15

FU1-22 to FU2-16

 

0.01

30.00 [Hz]

No

 

FU2-16

Jump Frequency 3 High

Jump Hi 3

16

FU2-15 to FU1-20

 

0.01

35.00 [Hz]

No

 

FU2-17

Start Curve for S-Curve

Start Curve

17

1 to 100 [%]

 

1

40%

No

 

Accel/Dedel Pattern

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-2

FU2-18

End Curve for S-Curve

End Curve

18

1 to 100 [%]

 

1

40%

No

 

 

Accel/Dedel Pattern

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU2-19

Input/Output Phase Loss

Trip select

19

 

00 to 11

 

-

00

Yes

6-2

Protection

 

 

(Bit Set)

 

FU2-20

Power ON Start Selection

Power-on run

20

No

 

 

0

-

No

Yes

6-2

Yes

 

 

1

 

 

 

 

 

 

 

 

 

 

 

FU2-21

Restart after Fault Reset

RST restart

21

No

 

 

0

-

No

Yes

6-2

Yes

 

 

1

 

 

 

 

 

 

 

 

 

 

 

FU2-22

Speed Search Selection

Speed Search

22

0000 to 1111

 

-

0000

No

 

 

(Bit Set)

 

 

 

 

 

 

 

 

 

 

 

 

 

FU2-23

Current Limit Level

SS Sup-Curr

23

80 to 200 [%]

 

1

100 [%]

Yes

 

During Speed Search

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-2

FU2-24

P Gain

SS P-gain

24

0 to 30000

 

1

100

Yes

 

 

During Speed Search

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU2-25

I Gain

SS I-gain

25

0 to 30000

 

1

1000

Yes

 

During speed search

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU2-26

Number of Auto Restart

Retry number

26

 

0 to 10

 

1

0

Yes

6-2

Attempt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17Code FU2-11 through FU2-16 appears only when FU2-10 is set to ‘Yes’.

5-6

Page 66
Image 66
HP 30 30 manual Function 2 Group FU2, Code Description Keypad Display Setting Range Units Factory