Chapter 6 - Parameter Description [EXT]

6.5 External Group [EXT]

EXT group appears only when an optional Sub-Board is installed.

EXT-00: Jump to Desired Code #

EXT► Jump code

001

Factory Default:

1

 

 

Jumping directly to any parameter code can be accomplished by entering the desired code number. This code is available only with LCD keypad.

EXT-01: Sub-Board Display

EXT►

Sub B/D

 

01

 

1

 

01

Sub-A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

Sub-A

 

 

1

 

This code automatically displays the types of Sub-Board installed.

Setting Range

Description

LCD

7-Seg

 

 

 

This board provides three multi-function

Sub-A

 

input terminals (P4, P5, P6), three multi-

1

function output terminals (Q1, Q2, Q3),

 

 

Load meter output (LM) and second input

 

 

frequency reference (V2).

 

 

This board provides encoder input

Sub-B

2

terminals (AOC, BOC / A+, A-, B+, B-),

encoder output terminals (FBA, FBB) and

 

 

 

 

power terminals (+5V input, Vcc output).

 

 

This board provides three multi-function

 

 

input terminals (P4, P5, P6), one multi-

Sub-C

3

function output terminal (Q1), isolated

 

 

second input frequency reference (V2) and

 

 

two analog meters (AM1, AM2).

 

 

Three multi-function input terminals (P4,

 

 

P5, P6), two multi-function output

Sub-D

4

terminals (Q1, Q2), Encoder input signal

A, B (LD/Open collector), isolated second

 

 

 

 

input frequency reference (V2) and Pulse

 

 

frequency reference

See ‘Chapter 7 - Options’ for more detail function, wiring, and terminal descriptions.

EXT-02 ~ EXT-04: Multi-Function Input Terminal Define (P4, P5, P6) – Sub-A, Sub-C

EXT►

P4 define

 

02

 

17

 

02

XCEL-L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

XCEL-L

 

 

17

 

An optional Sub-Board is needed if an application requires more than three multi-function input terminals.

‘Sub-A’ and ‘Sub-C’ boards provide additional three multi- function terminals. These terminals are used in conjunction with P1, P2 and P3 terminals. Refer to I/O-12 ~ I/O-14 for use. The following table shows the terminal definitions.

Setting Range

Description

LCD

7-Seg

 

Speed-L

0

Multi-Step Speed - Low

Speed-M

1

Multi-Step Speed - Mid

Speed-H

2

Multi-Step Speed - High

XCEL-L

3

Multi-Accel/Decel - Low

XCEL-M

4

Multi-Accel/Decel - Mid

XCEL-H

5

Multi-Accel/Decel - High

Dc-brake

6

DC injection braking during stop

2nd Func

7

Exchange to 2nd functions

Exchange

8

Exchange to commercial power line

iTerm Clear

9

Reserved for future use

Up

10

Up drive

Down

11

Down drive

3-Wire

12

3 wire operation

Ext Trip-A

13

External trip A

Ext Trip-B

14

External trip B

iTerm Clear

15

Used for PID control

Open-loop

16

Exchange between PID mode and

V/F mode

 

 

Main-drive

17

Exchange between Option and

Inverter

 

 

Analog hold

18

Hold the analog input signal

XCEL stop

19

Disable accel and decel

P Gain2

20

Used for PID control

SEQ-L

21

Sequence operation - Low

SEQ-M

22

Sequence operation - Mid

SEQ-H

23

Sequence operation - High

Manual

24

Exchange between Sequence

operation and Manual operation

 

 

Go step

25

Triggering Sequence operation

(Auto-B)

 

 

Hold step

26

Hold last step (Auto-A)

Trv Off.Lo

27

Used for Traverse Operation

Trv Off.Hi

28

 

Interlock1

29

Used for MMC operation

Interlock2

30

 

6-53

Page 145
Image 145
HP 30 30 manual EXT-00 Jump to Desired Code #, EXT-01 Sub-Board Display, Parameter Description EXT