HP 30 30 manual FU1-30 ~ FU1-37 User V/F Frequency and Voltage, 15.00

Models: 30 30

1 218
Download 218 pages 18.86 Kb
Page 100
Image 100

Chapter 6 - Parameter description [FU1]

Output Voltage

100%

Output

Frequency

Freq. Base

[V/F Pattern: ‘Square’]

Output Voltage

100%

 

 

FU1-37

 

 

FU1-35

 

 

FU1-33

 

 

FU1-31

 

Output

 

 

FU1-30

FU1-36

Frequency

 

FU1-32

FU1-34

Freq. Base

 

[V/F Pattern: ‘User V/F’]

 

FU1-30 ~ FU1-37: User V/F Frequency and Voltage

FU1► User freq 1

 

 

30

 

15.00

 

30

15.00 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

15.00 Hz

 

 

15.00

 

 

 

 

 

 

 

 

 

 

 

FU1► User volt 1

 

 

31

 

25

 

31

 

25 %

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

25 %

 

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU1► User freq 4

 

 

36

 

15.00

 

36

60.00 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

60.00 Hz

 

 

15.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU1► User volt 4

 

 

37

 

100

 

37

 

100 %

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Default:

100 %

 

 

 

100

 

 

 

 

 

 

 

 

 

 

These functions are available only when ‘User V/F’ is selected in FU1-29 [V/F pattern]. Users can make the custom V/F pattern by setting four points between FU1-22 [Starting Frequency] and FU1-21 [Base Frequency].

Output Voltage

100%

 

 

FU1-37

 

 

FU1-35

 

 

FU1-33

 

 

FU1-31

 

Output

 

 

FU1-30

FU1-36

Frequency

 

FU1-32

FU1-34

Freq. Base

 

[User V/F]

 

Note: When the ‘User V/F’ is selected, the torque boost of FU1-26 through FU1-28 is ignored.

6-16

Page 100
Image 100
HP 30 30 manual FU1-30 ~ FU1-37 User V/F Frequency and Voltage, 15.00