Dell R805 E1B01, Overcurrent, E2010 No Memory, E2011 Mem Config, Err, E2012 Unusable, Fail, E2015

Models: R805

1 200
Download 200 pages 56.14 Kb
Page 31
Image 31

Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1B01

USB#

Device plugged in the

Reseat the device cable. If

 

Overcurrent

specified USB port caused

the problem persists,

 

 

an overcurrent condition.

replace or remove the

 

 

 

device.

E2010 No Memory

No memory is installed in

 

the system.

Install memory. See "Installing Memory Modules" on page 117.

E2011

Mem Config

Memory detected, but is not

See "Troubleshooting

 

Err

configurable. Error detected

System Memory" on

 

 

during memory

page 150.

 

 

configuration.

 

E2012

Unusable

Memory is configured, but

See "Troubleshooting

 

Memory

not usable. Memory

System Memory" on

 

 

subsystem failure.

page 150.

E2013

Shadow BIOS

The system BIOS failed to

See "Troubleshooting

 

Fail

copy its flash image into

System Memory" on

 

 

memory.

page 150.

E2014

CMOS Fail

CMOS failure. CMOS RAM

See "Getting Help" on

 

 

not functioning properly.

page 175.

E2015

DMA

DMA controller failure.

See "Getting Help" on

 

Controller

 

page 175.

E2016

Int

Interrupt controller failure.

See "Getting Help" on

 

Controller

 

page 175.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on

 

 

 

page 175.

E2018

Prog Timer

Programmable interval

See "Getting Help" on

 

 

timer error.

page 175.

E2019

Parity Error

Parity error.

See "Getting Help" on

 

 

 

page 175.

E201A

SIO Err

SIO failure.

See "Getting Help" on

 

 

 

page 175.

E201B

Kybd

Keyboard controller failure.

See "Getting Help" on

 

Controller

 

page 175.

About Your System

31

Page 31
Image 31
Dell R805 E1B01, Overcurrent, E2010 No Memory, E2011 Mem Config, Err, E2012 Unusable, E2013 Shadow Bios, Fail, E2015