Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E201C

SMI Init

System management

See "Getting Help" on

 

 

interrupt (SMI)

page 175.

 

 

initialization failure.

 

E201D Shutdown Test BIOS shutdown test failure.

E201E POST Mem Test BIOS POST memory test failure.

E201F DRAC Config Dell remote access controller (DRAC) configuration failure.

E2020

CPU Config

CPU configuration failure.

E2021

Memory

Incorrect memory

 

Population

configuration. Memory

 

 

population order incorrect.

E2022

POST Fail

General failure after video.

E2110

MBE DIMM # &

One of the DIMMs in the

 

#

set implicated by "# & #"

 

 

has had a memory multi-bit

 

 

error (MBE).

See "Getting Help" on page 175.

See "Troubleshooting System Memory" on page 150. If problem persists, see "Getting Help" on page 175.

Check screen for specific error messages.

Ensure that DRAC cables and connectors are properly seated. If problem persists, see your DRAC documentation.

Check screen for specific error messages.

Check screen for specific error messages. See "Troubleshooting System Memory" on page 150.

Check screen for specific error messages.

See "Troubleshooting System Memory" on page 150.

32

About Your System

Page 32
Image 32
Dell R805 E201C SMI Init, E201E Post Mem Test Bios Post memory test failure, E2020 CPU Config, E2021 Memory, Population