Samsung SSA-S2000W user manual I/O time setup, Output Port Setting Table, English _

Models: SSA-S2000W SSA-S2000

1 51
Download 51 pages 43.68 Kb
Page 29
Image 29
I/O time setup

I/O time setup

Output Port Setting Table

You must specify the port settings using whatever combination of the followings if you want the device to operate in Secure mode or normal + Secure mode.

Port

Setting Value

Example

 

 

 

Operation mode setting value

 

EX 1)

 

 

If only the door relay operates in normal and

Operate only in Secure mode

00

Secure modes

 

 

Normal and Secure modes: 50

Operate in normal mode and Secure mode

50

Door Relay: +01

 

 

Operation port setting value

 

Output Port Setting Value: 51

 

 

 

Operate the door relay only

01

EX 2)

 

 

Operate the alarm relay only

02

If the alarm relay and the TTL output operate in

 

 

Secure mode

Operate the TTL output only

04

Secure Mode: 00

 

 

Alarm Relay, TTL: +06

Operate the door relay and TTL output

05

Output Port Setting Value: 06

 

 

Operate the alarm relay and TTL output

06

 

 

 

 

TO SPECIFY THE OUTPUT TIME IF THE CARD IS AUTHENTICATED

I/O TIME SETUP

You can specify the output time if the card ID is authenticated.

When the card ID is authenticated, the door relay and the TTL output operate for a set time.

1.Present the Master Card to the device.

2. Press Button 2 and Button 1 in sequence and press ENT .

3.Enter the two-digit door open time and press ENT .

4.Specify the two-digit TTL output time and press ENT .

For instance, if you set the door open time to “03” and TTL to “00”, the door relay operates for 3 seconds for an authenticated card ID.

By default, the door relay operates for “03” seconds while the TTL output works for “00” second in normal and Secure modes.

You can specify from 10 to 99.

X Y Z

\ ]

`

lzj W lu{

iŒ““

zzhTzYWWW

X Y Z

[\ ] ^ _ `

lzj W lu{

iŒ““

zzhTzYWWW

English _ 29

Page 29
Image 29
Samsung SSA-S2000W user manual I/O time setup, Output Port Setting Table, English _