installation and external connection

EXTERNAL READER CONNECTION

X Y Z

Wiegand DATA0(Pink)

[ \ ]

Wiegand DATA0(Sky blue)

^_ `

lzj W lu{

iŒ““

zzhTzYWWW

검은색-

GND

(+)

빨간색+

DC+12V

(-)

- Proximity Reader Connection

1.Connect the DC 12V(+) of the power supply unit to the plus (+) line of the reader.

2.Connect the GND(-) line of the power supply unit to the minus (-) line of the reader.

3.Connect the Wiegand data input line 0 of the proximity reader to the purple line.

4.Connect the Wiegand data input line 1 of the proximity reader to the sky blue line.

For a list of compliant readers (external readers), see the followings: - Standard 26bit Wiegand format proximity reader

14_ Installation and External Connection

Page 14
Image 14
Samsung SSA-S2000W user manual External Reader Connection