I/O time setup

TO SPECIFY THE ALARM OPERATION TIME FOR AUX 2

1.Present the Master Card to the device.

2. Press Button 2 and Button 6 in sequence and press ENT .

3.Refer to the output port table on page 29 and specify a desired output mode.

If you want the alarm relay alone to operate in normal and Secure modes in case of an input through the auxiliary port, select the

< 5 2 > buttons and press ENT .

4.Enter the two-digit door relay output time and press ENT .

5.Enter the two-digit alarm relay output time and press ENT .

6.Enter the two-digit TTL relay output time and press ENT .

You can specify a two-digit time from 00 to 99 seconds.

By default, all output times are set to “00”.

 

X

Y

Z

 

 

\

]

 

 

 

`

tˆš›Œ™Gjˆ™‹

lzj

W

lu{

 

 

iŒ““

 

 

 

 

 

zzhTzYWWW

 

X

Y

Z

 

[

\

]

 

^

_

`

 

lzj

W

lu{

 

iŒ““

 

 

 

 

 

zzhTzYWWW

MOther output ports that are not specified for the output mode will not be activated. For instance, if you set the output mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the alarm relay will operate.

TO SPECIFY THE ALARM OPERATION TIME FOR AUX 3

1.Present the Master Card to the device.

2. Press Button 2 and Button 7 in sequence and press ENT .

3.Refer to the output port table on page 29 and specify a desired output mode.

If you want the alarm relay alone to operate in normal and Secure modes

in case of an input through the auxiliary port, select the < 5

2 >

buttons and press ENT .

 

4.Enter the two-digit door relay output time and press ENT .

5.Enter the two-digit alarm relay output time and press ENT .

6.Enter the two-digit TTL relay output time and press ENT .

You can specify a two-digit time from 00 to 99 seconds.

By default, all output times are set to “00”.

 

X

Y

Z

 

 

\

]

 

 

 

`

tˆš›Œ™Gjˆ™‹

lzj

W

lu{

 

 

iŒ““

 

 

 

 

 

zzhTzYWWW

 

X

Y

Z

 

[

\

]

 

^

_

`

 

lzj

W

lu{

 

iŒ““

 

 

 

 

 

zzhTzYWWW

MOther output ports that are not specified for the output mode will not be activated. For instance, if you set the output mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the alarm relay will operate.

32_ I/O Time Setup

Page 32
Image 32
Samsung SSA-S2000W user manual 32 I/O Time Setup